  universal ac input / full rangebuilt-in active pfc function, pf>0.95 protections: short circuit / overload / over voltage / over temperature dc ok signal emote on-off control standby 5v@0.3ano load power consumption<0.75w (note.7) current sharing up to 2400w (3+1) (24v,36v,48v) 5 years warranty high efficiency up to 89%withstand 300vac surge input for 5 seconds built-in cooling fan on-off control built-in built-in r built-in remote sense function specification hrpg-600-3.3 hrpg-600-5 hrpg-600-7.5 HRPG-600-12 hrpg-6 00-15 hrpg-600-24 hrpg-600-36 hrpg-600-48 model dc voltage rated current current range rated power ripple & noise (max.) note.2 output voltage adj. range voltage tolerance note.3 line regulation load regulation setup, rise time hold up time (typ.) voltage range note.5 frequency range power factor (typ.) efficiency (typ.) input environment inrush current (typ.) leakage current over temperature safety standards harmonic current emi conduction & radiation safety & function ems immunity emc (note 4) withstand voltage isolation resistance working temp. dc ok signal remote control working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload over voltage protection ac current (typ.) 3.3v 5v 7.5v 12v 15v 24v 36v 48v 120a 120a 80a 53a 43a 27a 17.5a 13a 0 ~ 120a 0 ~ 120a 0 ~ 80a 0 ~ 53a 0 ~ 43a 0 ~ 27a 0 ~ 17.5a 0 ~ 13a 396w 600w 600w 636w 645w 648w 630w 624w 100mvp-p 100mvp-p 100mvp-p 120mvp-p 150mvp-p 150mvp-p 200 mvp-p 240mvp-p 2.8 ~ 3.8v 4.3 ~ 5.8v 6.8 ~ 9v 10.2 ~ 13.8v 13.5 ~ 18v 21.6 ~ 28.8v 28.8 ~ 39.6v 40.8 ~ 55 .2v 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 1000ms, 50ms/230vac 2500ms, 50ms/115vac at full load 16ms/230vac 16ms/115vac at full load 85 ~ 264vac 120 ~ 370vdc 47 ~ 63hz pf>0.94/230vac pf>0.99/115vac at full load 78.5% 82% 6 ~ 7v 9.4 ~ 10.9v 14.4 ~ 16.8v 18.8 ~ 21.8v 30 ~ 34.8v 41.4 ~ 48.6v 57.6 ~ 67.2v 86% 88% 88% 88% 89% 89% 8.5a/115vac 5a/230vac 35a/115vac 70a/230vac <1.2ma / 240vac 105 ~ 135% rated output power 3.96 ~ 4.62v protection type : constant current limiting, recovers automatically after fault con dition is removed protection type : shut down o/p voltage, re-power on to recover protection type : shut down o/p voltage, recovers automatically after t emperature goes down 80 5 (tsw1)detect on heatsink of power transistor 90 5 (tsw2) for 3.3v,5v,7.5v ; 100 5 (tsw2) power for others detect on heatsink of power doide detect on main output choke ul60950-1, tuv en60950-1 approved compliance to en55022 (cispr22) class b compliance to en61000-3-2,-3 compliance to en61000-4-2,3,4,5,6,8,11, env50204, en55024, en 61000-6-2, heavy industry level, criteria a i/p-o/p:3kvac i/p-fg:1.5kvac o/p-fg:0.5kvac i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh -40 ~ +70 (refer to output load derating curve) rc+ / rc-: 4 ~ 10v or open = power on ; 0 ~ 0.8v or short = power off psu turn on : 3.3 ~ 5.6v ; psu turn off : 0 ~ 1v 20 ~ 90% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 50 ) 10 ~ 500hz, 5g 10min./1cycle, 60min. each along x, y, z axes 147.7k hrs min. mil-hdbk-217f (25 ) 218*105*63.5mm (l*w*h) file name:hrpg-600-spec 2010-11-29 features : 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 5. derating may be needed under low input voltages. please check the derati ng curve for more details. 6. length of set up time is measured at first cold start. turning on/off the powe r supply may lead to increase of the set up time. 7. no load power consumption<0.75w when rc+ & rc- (cn100 pin3,4) 0 ~ 8v or short. for guidance on how to perform these emc tests, please refer to ?emi testing of c omponent power supplies.? (as available on http://www.meanwell.com) h r p g - 6 0 0 s e r i e s 600w single output with pfc function 1.58kg;8pcs/13.6kg/1.34cuft 5v standby 5vsb : 5v@0.3a ; tolerance 5%, ripple : 50mvp-p(max.) fan control (typ.) load 35 15% or rth2 50 fan on
mechanical specification mechanical specification case no. 977a unit:mm ac input terminal pin no. assignment dc output terminal pin no. assignment pin no. pin no. 1 1~3 3 2 4~6 assignment assignment ac/n +v ac/l -v fg derating curve output derating vs input voltage input voltage (v) 60hz ta = 25 90 100 125 135 155 264 100 90 80 70 60 50 40 load(%) ambient temperature ( ) load (%) -40 0 10 20 30 40 50 60 70 20 50 80 100 125 (horizontal) pw fosc : 70khz m cn100 led (vo adj.)svr1 block diagram pin no. pin no. 7 6,8 5 3 2 1 9 4 10 assignment -s +s dc-ok gnd cs assignment rc- rc+ aux auxg mating housing terminal or equivalent or equivalent connector pin no. assignment(cn100) : hrs df11-10dp-2ds or equiva lent hrs df11-10ds hrs df11-**sc o.l.p. o.t.p. emi inrush active filter current limiting rectifiers & pfc i/p fg pwm pfc circuit sharing detection current power aux switching power filter filter & & rectifiers rectifiers +v +s aux control control o.v.p. o.t.p. remote control -v -s auxg rc+ cs dc ok rc- 105 18max. 11 9.2 o/p 12 3 4 5 6 air flow direction 63.5 3 2 1 i/p 4-m4 l=6 12max. 8.2 63.5 20.75 10 218 32.8 152.4 8-m4 l=4 (both sides) 32.8 38.3 12.5 152.4 600w single output with pfc function file name:hrpg-600-spec 2010-11-29 h r p g - 6 0 0 s e r i e s 1 2 9 10
the remote sensing compensates voltage drop on the load wiring up to 0.5v. 10 10 9 9 cn100 aux rc- gnd gnd -s auxg rc+ cs dc-ok +s 2 2 1 1 1.remote sense 11 99 10 10 sense lines should be twisted in pairs load - + +s -s (pin9) (pin10) fig 1.1 between dc-ok(pin4) and gnd(pin3) 3.3 ~ 5.6v 0 ~ 1v output status on off dc-ok signal is a ttl level signal. high when psu turns on. cn100 aux rc- gnd gnd -s auxg rc+ cs dc-ok +s 2.dc-ok signal fig 2.1 cn100 cn100 22 5 cs current sharing signal. when units are connected in parallel, the cs pins o f the units should be connected to allow current balance between units. 7 dc-ok dc-ok signal is a ttl level signal, referenced to pin8(dc-ok gnd). high w hen psu turns on. 9 +s positive sensing. the +s signal should be connected to the positive term inal of the load. the +s and -s leads should be twisted in pair to minimize noise pick-up effect. the maximum line drop compensation i s 0.5v. 10 -s negative sensing. the -s signal should be connected to the negative term inal of the load. the -s and +s leads should be twisted in pair to minimize noise pick-up effect. the maximum line drop compensation i s 0.5v. 6,8 gnd this pin connects to the negative terminal(-v). return for dc-ok signal o utput. 600w single output with pfc function file name:hrpg-600-spec 2010-11-29 h r p g - 6 0 0 s e r i e s function description of cn100 pin no. function description function manual 3 4 rc+ rc- remote control ground. turns the output on and off by electrical or dry contact between pin 4 (rc-), sho rt: power off, open: power on. 2 1 aux auxg auxiliary voltage output, 4.75~5.25v, referenced to pin 1(auxg). t he maximum load current is 0.3a. this output has the built-in oring diodes and is not controlled by the "remote on/off control". auxiliary voltage output ground. the signal return is isolated from th e output terminals (+v & -v).
10 9 2 1 1 9 10 cn100 2 600w single output with pfc function file name:hrpg-600-spec 2010-11-29 h r p g - 6 0 0 s e r i e s between rc+(pin3) and rc-(pin4) sw on (short) sw off (open) output status off on the psu can be turned on/off by using the "remote control" function. sw cn100 aux rc- gnd gnd -s auxg rc+ cs dc-ok +s 3.remote control fig 3.1 psu2 psu1 psu3 psu4 fig 4.1 load sense lines should be twisted in pairs +v -v -v -v -v -v cn100 cn100 cn100 cn100 +v +v +v +v 10 10 10 10 9 9 9 9 aux aux aux aux rc- rc- rc- rc- gnd gnd gnd gnd gnd gnd gnd gnd -s -s -s -s auxg auxg auxg auxg rc+ rc+ rc+ rc+ cs cs cs cs dc-ok dc-ok dc-ok dc-ok +s +s +s +s 2 2 2 2 cn100 cn100 psu2 psu1 psu3 psu4 cn100 cn100 1 1 1 1 note : 1.in parallel connection, maybe only one unit (master) operate if th e total output load is less than 2% of rated load condition. the other psu (slave) may go into standby mode and its output led and relay will no t turn on. 2.2% min. of dummy load is required. 4.current sharing with remote sensing (only for 24v, 36v and 48v) hrpg-600 has the built-in active current sharing function and can be conn ected in parallel to provide higher output power : (1)parallel operation is available by connecting the units shown as bel ow. (2)difference of output voltages among parallel units should be less th an 2%. (3)the total output current must not exceed the value determined by the fol lowing equation. (4)in parallel operation 2 units is the maximum, please consult the manuf acturer for applications of more connecting in parallel. (5)the power supplies should be paralleled using short and large diamet er wiring and then connected to the load. (+s,-s,cs and gnd are connected mutually in parallel). (output current at parallel operation)=(rated current per unit) (n umber of unit) 0.9


▲Up To Search▲   

 
Price & Availability of HRPG-600-12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X